Residential solar
A solar array converts daylight into electricity used on site, cutting what a home draws from the grid and, with storage, keeping essential circuits alive when the grid goes down. Good systems start with a shade study and twelve months of actual kWh consumption, not a panel count pulled from a brochure.
What this covers
The jobs that fall under solar, and what each one actually involves.
Grid-tied arrays laid out around obstructions and rafter positions, with the string design set by the roof's real usable planes rather than its total area.
Pole or ballasted racking for sites where the roof is shaded, too small or too complex, with tilt and azimuth set for the site's own production curve.
Storage sized to the loads that must ride through an outage, wired to a protected subpanel so backup power reaches those circuits and not the whole house.
String, microinverter or optimizer topology chosen by shading pattern, since partial shade on one panel behaves very differently in each configuration.
Service and busbar work to satisfy the interconnection rule, the constraint that most often decides whether an array can be added without a panel change.
Mounts landed on structure and flashed into the roof covering, so an array adds twenty years of penetrations without adding a single leak path.
Structural and electrical permits, utility application and the inspection sequence, handled in the order that avoids a system sitting finished but not energised.
Production monitoring at panel or string level, so a failing optimizer or a soiled section shows up as a data anomaly instead of a quiet yearly loss.
Level 2 charging tied into the same service work as the array, with load calculations that account for the charger and the solar backfeed together.
Compare options
Most solar decisions come down to three linked choices: the module technology on the roof, how DC power is converted to AC, and whether to add storage. Each affects cost, output on an imperfect roof, and how the system behaves over twenty-plus years. The right combination depends far more on the specific roof planes, shading, and utility tariff than on any single product being objectively best.
Why it matters
A correctly sized array can cover a meaningful share of a household's annual kilowatt-hours, replacing purchased energy with on-site generation. Output still swings with season and weather, so the offset is measured across a full year rather than any single month.
Modules carry published degradation curves, typically around 0.3-0.5% of rated output lost per year after a slightly larger first-year drop, so production twenty years out can be modeled rather than guessed.
Solar alone shuts down during an outage for line-worker safety. Adding a battery and switchgear with islanding capability keeps selected circuits running while the grid is down.
Electricity generated on the roof is consumed at the point of use, avoiding the losses that come with moving power across transmission and distribution lines and displacing whatever mix the local grid is running.
How the work happens
Twelve months of utility bills establish annual kWh use and load patterns. A roof inspection confirms structure, rafter spacing, remaining roof life, and available planes, while a shade study maps obstructions across the seasons. The main service panel is checked for busbar capacity to accept a solar backfeed.
Array layout, module count, and inverter architecture are set against the measured roof planes and shading. Modeling software produces month-by-month kWh estimates using local weather data, and the design is checked against setback, fire-access, and rapid-shutdown code requirements as well as the utility's interconnection limits.
Structural and electrical plans go to the local building authority, and a separate interconnection application goes to the utility. Utility approval to energize is a distinct step from the building permit, and its timeline is set by the utility. Some jurisdictions require a stamped engineering review or a service upgrade before approval.
Racking is anchored to structural members with every penetration flashed and sealed, modules are mounted and wired, and the inverter, disconnects, and any battery are tied into the service panel. After the jurisdiction's inspection and the utility's permission to operate, the system is commissioned and monitoring is verified against the modeled production.
Good work on a home is rarely the thing you notice — it is the leak that never happens, the draught you stop feeling, the bill that stops climbing.
Budgeting
Solar quotes vary widely. These are the variables that explain most of the difference between one estimate and another.
Questions
Start with annual kilowatt-hour consumption, which appears on twelve months of utility bills, rather than a rule of thumb about house size. A designer then models how many kWh each panel will produce on that specific roof, accounting for orientation, tilt, latitude, local weather data, and shading, then divides the target offset by that per-panel yield. Two identical-looking homes can need very different arrays: an all-electric house with a heat pump and an EV may use two to three times the electricity of a gas-heated neighbor. The roof is often the real constraint, since only planes with adequate unshaded area and acceptable orientation can be used.
In the northern hemisphere, south-facing planes produce the most, but east- and west-facing roofs typically still deliver roughly 80 to 85% of a south-facing array's annual output, which is often perfectly viable. Pitch matters less than most people expect across a broad range of angles. Shading is the bigger issue: a chimney, vent stack, or tree that clips part of the array for a few hours a day can cut production disproportionately on a plain string system, which is exactly where microinverters or DC optimizers earn their added cost by isolating the affected modules. A site assessment should include a shade study across the full year, not just a summer afternoon.
A standard grid-tied system without storage shuts down automatically during an outage. This is a code requirement known as anti-islanding, and it exists so the array cannot energize utility lines that crews are repairing. To keep power during an outage you need a battery plus equipment that can disconnect the home from the grid and form its own stable microgrid. Most homeowners back up a defined set of critical loads such as the refrigerator, well pump, internet, and a few lighting and outlet circuits through a subpanel, because whole-home backup requires far more battery power and capacity.
Crystalline silicon modules commonly carry 25 to 30 year performance warranties and often keep producing usefully beyond that at reduced output. Manufacturers publish an annual degradation rate, typically in the range of 0.3 to 0.5% per year for quality monocrystalline modules after a slightly larger first-year drop, so an array may still deliver roughly 85 to 90% of its original output after 25 years. These are industry-typical ranges rather than guarantees; the specific module datasheet and warranty govern. The panels are usually not the first thing to need attention: string inverters commonly have a 10 to 15 year service life and may need replacement once during the array's lifetime, while microinverters generally carry warranties of around 25 years.
Net metering rules determine what exported kilowatt-hours are credited at, and after system cost they are the biggest variable in the economics. Under full retail net metering, exported energy offsets imported energy at the same rate, so the grid effectively acts as a battery. Many utilities have moved to net billing or export-rate structures that credit exports at a lower wholesale or avoided-cost rate, sometimes varying by time of day; under those structures self-consumption becomes more valuable, which strengthens the case for storage or for shifting large loads into daylight hours. These tariffs, along with any incentive programs, vary by location and change over time, so verify the rules currently in force with your utility and check current local programs before assuming any payback figure.
Get a quote for the work described on this page. You will be taken to our quote partner to continue.